Over 100 Washington Auctions End Today - Bid Now

spacer
Listing 4517683 Listing 4517683 Listing 4517683 Listing 4517683 Listing 4517683
Listing 4517683 Listing 4517683 Listing 4517683 Listing 4517683 Listing 4517683

For Sale QIAGEN QIAcube DNA/RNA Purification System

  • Asking Price :$1,899.99 USD [convert]
  • Condition : Used - Good
  • Qty. Available : 2
  • In Stock : Yes
  • Date : April 29, 2024
  • Listing # : 4517683
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4517683

  • Condition: Used - Good
  • Brand: QIAGEN
  • Type: DNA Related
  • Model: QIAcube
Technical data
Power: 100–240 V AC, 50/60 Hz, 650 VA Mains supply voltage fluctuations are not to exceed 10% of nominal supply voltages.
Note: The apparent power can exceed 650 VA for up to 2 seconds during the centrifuge acceleration and can reach an approximate value of 1000 VA.; Fuse: 2x T6.3A L 250V; Overvoltage category: II
Operating temperature:
18 to 28ºC (64.4 to 82.4ºF)

Relative humidity
15–75% (non-condensing)

Place of operation:
For indoor use only
Pollution level 2

Environmental class:
3K2 (IEC 60721-3-3)

Storage conditions temperature:
15ºC to 30ºC (59ºF to 86ºF) in manufacturer’s package; Relative humidity: Max. 75% (non-condensing); Environmental class: 1K2 (IEC 60721-3-1)

Instrument dimensions
Dimensions (hood closed): width 65 cm (25.6 in.), height 58 cm (22.8 in.), depth 62 cm (24.4 in.); Dimensions (hood open): width 65 cm (25.6 in.), height 86 cm (34 in.), depth 62 cm (24.4 in.); Mass: QIAcube Connect: 71.5 kg (157.6 lb.), Accessories: 3 kg (6.6 lb.)

Centrifuge
10,640 rpm maximum, 12,000 x g maximum, swing-out rotor maximum 45°, 12 rotor positions
Shaker Speed 100–2000 rpm, amplitude 2 mm, heating range of ambient temperature to 70°C (158°F), ramp-up time of <5 minutes from ambient temperature to 55°C (±3°C). Difference in the temperature detected by the internal sensor and the temperature of the sample liquid is approximately –2°C.

Pipetting system:
Syringe size 1 ml, pipetting range 5–900 µl
Table capacity Up to 12 samples per run

Data output
USB stick: USB2.0; Compatible OS: Windows 8, Windows 7, Windows Vista, Windows XP (SP3 or later); Mac OS x 10,1 or later; Operating temperature range: 0ºC to 35ºC; Operating humidity range: 10 to 90% (with no condensation); Storage temperature range: –20ºC to 60ºC (–4ºF to 140ºF); Storage humidity range: 10 to 90% (with no condensation); Formatting: FAT32

UV lamp
Wavelength: 278nm; Optical power: 200-300mW

Software
QIAGEN protocols are pre-installed on the QIAcube Connect.
Altitude Up to 2000 m (6500 ft)

Transportation conditions
–25°C to 60°C (–13°F to 140°F) in manufacturer's package; Max. 75% relative humidity (non-condensing); Environmenal class: 2K2 (IEC 60721-3-2)Technical data Power: 100–240 V AC, 50/60 Hz, 650 VA Mains supply voltage fluctuations are not to exceed 10% of nominal supply voltages. Note: The apparent power can exceed 650 VA for up to 2 seconds during the centrifuge acceleration and can reach an approximate value of 1000 VA.; Fuse: 2x T6.3A L 250V; Overvoltage category: II
Operating temperature 18 to 28ºC (64.4 to 82.4ºF)

Return Policy