SIEMENS Siremobil 2000 5c C-Arm

Description

Technische Daten

Model Rating

Not Rated
Rate This Model Now
Information Provided By:
The mobile C-arm MULTIMOBIL 5C provides the optimum solution of today's clinical requirements. It is ideally suited for entry level surgery in many application fields such as orthopedics, trauma surgery, general surgery.

Special Features
◾Standby mode eliminates accidental radiation release during transportation
◾Image rotation for visualization of images irrespective of position of organ
◾Thermal protection

Mobile C-arm Image Intensifier System with High Frequency Technology
Can be used for therapeutic procedures in
◾OR
◾Radiological departments
◾Emergency rooms

The automatic dose regulation constantly adapts the X-ray radiation to the thickness and density of the irradiated body part.

Extension with digital image memory provides storage for four fluoroscopy images. This simplifies the diagnosis while reducing in radiation dose and total fluoroscopy time.

High resolution compact image intensifier system with
◾CCD camera
◾Excellent spatial resolution with 0.5 and 1.5 focal spots

Single-tank high-frequency X-ray generator
◾Automatic dose regulation

Digital control unit with
◾Four image storages
◾Last Image Hold (LIH)

All components are ideally matched for delivering consistent image quality.

C-arm
Orbital movement 125° (-35° to +90°)
Angulation ±190°
Horizontal movement 20 cm (7.9")
Swivel range ±12.5°
Vertical Travel 40 cm (15.7")
Source - I.I. distance 86 cm (33.8")
Immersion depth 63.5 cm (25")
Lateral movement steering handle

X-ray generator


Type 2.5 kW/190-240 V; 1.6 kW/110 V
Radiographic parameters
kV range 40 kV to 100 kV in 20 steps
mAs 0.32 mAs to 200 mAs in 29 steps
mA 13 mA to 63 mA/190-240 V; 10 mA to 40 mA/110V
Time 20 ms to 5 s/190-240 V; 20 ms to 8 s/110 V
Fluoroscopic parameters
Fluoroscopy voltage 40 kV to 110 kV
mA range anti-isowatt 0.5 mA to 5 mA
contrast 0.5 mA to 7 mA
Fluoroscopy ADR (Automatic Dose Regulation) and manual mode

X-ray tube unit


Type stationary anode dual focus
Focal spot sizes, minimal value 0.5/1.5 mm
Selection automatic selection of focal spot for fluoroscopy and radiography
Thermal protection auto cut-off of fluoroscopy and radiography in case of tube head
temperature exceeding 60 °C
Collimator system motorized iris collimator for concentric collimation

X-ray image intensifier


Nominal diameter 23 cm (9")
Field size dual field 23 cm (9")/16 cm (6") selectable from the control panel
circular grid placed at the input of the I.I.
Grid Pb 8:1; 40 lp/cm, f0 90

Cassette holder


Format auto centering 10" x 12" format

TV system


Type CCD camera with high sensitivity and resolution
TV standard CCIR 625 lines at 50 Hz
Matrix size of CCD camera 752 (H) x 582 (V) for 50 Hz effective pixel
Image rotation endless clockwise and anti clockwise
Image reversal left/right and top/bottom
Displays 2 x 15" black and white TFT displays for live image and
Last Image Hold (LIH)
high brightness, high resolution with independent
brightness and contrast control
Digital image storage capacity standard four frame image memory in addition to LIH

Power Supply


Power requirement maximum 3.5 kVA
Main voltage single phase 110V AC ± 10%, 50 Hz and 60 Hz
at line resistance of 0.36 ohms
single phase 190V - 240V AC ± 10%, 50 Hz and 60 Hz
at line resistance of 1.5 ohms

Accessories


Cloth cover and clips for C-arm, X-ray tube and I.I.
Cassette holder standard
Interface to external recording device optional
Thermal printer optional

Environment conditions (operating)

Temperature range +10ºC to +40ºC
Relative humidity 30% to 75%
Barometric pressure 700hPa to 1060hPa

 

Reviews

Forums

Share your opinion or experience with this equipment - Review this model

Diagnostic Imaging Training: RSTI (Radiological Service Training Institute)

15,000 service professionals from over 50 different countries have trained in over 35 courses in radiology, mammography, CT, ultrasound, networking, PACS, & DICOM. Classroom & lab facilities to accommodate up to 60 students. DOTmed 100

Werben
Erhöhen Sie Ihren Bekanntheitsgrad
Auktionen + Privatverkäufe
Den besten Preis erzielen
Geräte/Geräteteile kaufen
Den günstigsten Preis finden
Daily News
Die neuesten Nachrichten lesen
Übersicht
Alle DOTmed Benutzer durchsuchen
Ethik auf DOTmed
Unseren Ethik-Standard anzeigen
Gold-Parts Verkäufer-Programm
PH-Anfragen erhalten
Gold Service Dealer-Programm
Anfragen empfangen
Gesundheitsdienstleister
Alle Gesundheitsdienstleister-Tools anzeigen
Jobs/Training
Einen Job suchen
Parts Hunter +EasyPay
Angebote für Geräteteile erhalten
Kürzlich zertifiziert
Kürzlich zertifizierte Benutzer anzeigen
Kürzlich bewertet
Kürzlich zertifizierte Benutzer anzeigen
Rental Central
Geräte billiger mieten
Geräte/Geräteteile verkaufen
Das meiste Geld erhalten
Service-Techniker Forum
Hilfe und Beratung finden
Einfache Angebots-Anfrage
Angebote für Geräte erhalten
Virtuelle Messe
Service für Geräte finden
Access and use of this site is subject to the terms and conditions of our LEGAL NOTICE & PRIVACY NOTICE
Property of and Proprietary to DOTmed.com, Inc. Copyright ©2001-2018 DOTmed.com, Inc.
ALL RIGHTS RESERVED