Over 90 Total Lots Up For Auction at One Location - WA 04/08

spacer
Listing 1570947 Listing 1570947 Listing 1570947
Listing 1570947 Listing 1570947 Listing 1570947

For Sale CARL ZEISS Humphrey 745 Visual Field Analyzer

  • Asking Price :$9,875.00 USD [convert]
  • Condition : Used - Good
  • Qty. Available : 1
  • In Stock : Yes
  • Date : February 26, 2024
  • Listing # : 1570947
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #1570947

  • Condition: Used - Good
  • Brand: CARL ZEISS
  • Type: Visual Field Analyzer
  • Model: Humphrey 745
  • MPN: 745
  • Warranty: 60 Days
  • Bowl Illumination: 31.5 ASB
  • Humidity: 20-85%
  • Max Horizontal Range: 86 Degrees
  • Max Wet Bulb: 78 F
  • Maximum Stimulus Intensity: 10,000 ASB
  • Operating Temperature: 41-95 F
  • Stimulus Duration: 200 msec
  • Stimulus Wavelength: 30 cm
(1) PRE-OWNED AND IN VERY GOOD CONDITION
ZEISS / HUMPHREY FIELD ANALYZER II 745 / HFA II 745 WITH WHEELCHAIR ACCESSIBLE ROLLING POWER TABLE & PRINTER


-GPA (GLAUCOMA PROGRESSION ANALYSIS) ENABLED-


*This Unit Has Been Inspected, Tested, Calibrated AND Completely Verified By A FACTORY-TRAINED HUMPHREY / ZEISS Equipment Technician.

IT IS READY TO GO TO WORK IN YOUR OFFICE OR CLINIC TODAY!!


Measures/Output: Sensitivity of the visual field using White-On-White or Blue - Yellow stimuli


Sample Clinical Use: Glaucoma assessment, pathology of the anterior and posterior visual pathways


-GPA (GLAUCOMA PROGRESSION ANALYSIS) ENABLED-

-GAZE TRACKING-

-SOFTWARE VERSION: 14.2.1-


Warranty:

60-Day Warranty On The Visual Field Analyzer - Warranty Is Based Upon Performance


OFFER INCLUDES:

(1) ZEISS/HUMPHREY 745 VISUAL FIELD ANALYZER; FEATURES BLUE - YELLOW (SWAP-Short Wavelength Automated Perimetry) Testing

(1) PATIENT RESPONSE BUTTON

(1) WHEELCHAIR ACCESSIBLE POWER TABLE AND PRINTER

(1) KEYBOARD

CALIBRATION DISK


PLEASE NOTE THE FOLLOWING:

-NO TAPE BACK-UP

-OPERATING MANUAL AVAILABLE BY DOWNLOAD ONLY

-NEW BULB


The Purpose Of Visual Field Testing, Or Perimetry, Is To Provide Information Critical To:

-Diagnosing Ocular Diseases, Especially Glaucoma

-Evaluating Neurological Diseases

-Monitoring The Progress Of Ocular And Neurological Diseases


Visual field testing can lead to early detection and treatment of disease. In the case of glaucoma, visual fields play a major role in identifying visual field defects and evaluating the efficacy of the therapy used to control the disease process.

When evaluating visual performance, clinicians are primarily interested in two retinal tests measure functions: resolution and contrast sensitivity. Resolution is the ability to identify discrete forms (letters, numbers, symbols), and is commonly measured with the visual acuity test. Resolution rapidly diminishes with increasing distance from the fovea and is, therefore, a poor indicator of overall visual performance.

A better means of evaluating visual function—especially those areas less sensitive than the fovea—is contrast sensitivity testing. Contrast sensitivity is the ability to detect a stimulus (spot of light or other target) against a darker or brighter background. Standard Humphrey perimetry may be thought of as contrast sensitivity testing applied throughout the peripheral visual field.

In perimetry, the term “threshold” is used to describe a very specific level of stimulus detection. The threshold represents the point at which a stimulus is seen 50% of the time and missed 50% of the time. The assumption is that all stimuli brighter than the threshold value will be seen and all stimuli dimmer will be missed. Reviewing the threshold value at each point tested in the visual field is an important part of the diagnostic process.

Visual field tests can yield information that is general in nature, as with screening tests, or more exacting and quantitative, as with threshold tests. In deciding which test type is most appropriate for a patient the practitioner is influenced by many factors, including the patient’s presenting complaint, family history, age, degree of cooperation, and time available to run the test.


Methods Of Testing The Visual Field:

-Kinetic Testing

-Static Threshold Testing

*Above information was provided by Humphrey Field Analyzer II User's Guide


*This Unit Has Been Inspected, Tested, Calibrated AND Completely Verified By A FACTORY-TRAINED HUMPHREY / ZEISS Equipment Technician.

IT IS READY TO GO TO WORK IN YOUR OFFICE OR CLINIC TODAY!!


Warranty:

60-Day Warranty On The Visual Field Analyzer - Warranty Is Based Upon Performance

*LTL FREIGHT SHIPPING COST OF $595 INCLUDES PROFESSIONAL WOOD CRATING, INSURANCE AND DELIVERY INTO YOUR OFFICE*
Seller Information
Ozark Products
Citi Capital Groupspacer
Send the Seller a message: