The Allied Healthcare AutoVent 4000 Transport Ventilator is the next generation in state-of-the-art emergency transport ventilators.

Note: Oxygen source is not included.

Warranty: 1 Year - Free from Material Defects in Material and Workmanship.

The AutoVent 4000 Series Transport Ventilator is pneumatically powered with a manual breath button and anti-breath stacking that's standard for all configurations. Each model is equipped with independent settings for measuring Breaths Per Minute, Inspiratory Time, Tidal Volume, and Airway Pressure Relief. Each unit is also equipped with a large, color-coded manometer gauge and a full set of alarms for patient safety and optimal device performance.

The Life Support Products AutoVent 4000 series now can deliver CPAP and emergency ventilation in one compact unit. Customers have the choice of the base unit, along with additional options of integrated CPAP, electronic alarms, and/or an air mix mode.

AutoVent 4000CPAP Pneumatically Powered Ventilator and CPAP Generator:

The AutoVent 4000CPAP, in Ventilation mode, delivers a time cycled constant flow breath. The inspiratory time is constant and the breath volume is varied by changing the flow rate into the patient. Various breaths per minute are achieved by varying the expiratory time.

The CPAP function delivery Continuous Positive Airway Pressure to the spontaneously breathing patient and is used in place of, and not in conjunction with, forced ventilation.

The AutoVent 4000CPAP is intended to be used as a gas powered emergency ventilator which, in ventilation mode, is designed to provide emergency respiratory support by means of a face mask or tube inserted into the patient's airway.

Allied Healthcare AutoVent 4000 Transport Ventilator Features
  • Durable and light.
  • Pneumatically powered.
  • Adjustable tidal volume, BPM, and pressure relief with alarm.
  • Child and adult settings.
  • Internal demand valve.
  • Anti-breath stacking.
  • Manometer readout.
  • Low source gas pressure alarm.
  • Color-coded labels and gauge for initial settings.
  • Manual breath button.
  • Capable of providing ventilation and CPAP in one unit.
  • Optional Air Mixing provides 65% O2 concentration to lengthen cylinder life on long transports.
Allied Healthcare AutoVent 4000 Transport Ventilator Specifications
  • Gas Supply Pressure: 40.6 to 87.0 psi oxygen DISS.
  • Breaths Per Minute:
    • Accuracy: +/- 10%.
    • Range: 1 second inspiratory time = 0 to 30 bpm.
    • Range: 2 second inspiratory time = 0 to 20 bpm.
  • Tidal Volume:
    • Accuracy: +/- 10% with 100% oxygen.
    • Range: 1 second inspiratory time = 200 to 600 ml.
    • Range: 2 second inspiratory time = 400 to 1200 ml.
  • Inspiratory Time Accuracy: +/- 10%.
  • Safety Pressure Relief: Adjustable from 20 to 80 cm H2O +/- 10%.
  • Low Source Gas Alarm: Activates at 275 to 262 kPa (40 to 38 psi) source pressure.
  • Oxygen Inlet Filter: 65 micron sintered bronze.
  • Burst Pressure: 250 psig (1724 kPa) minimum.
  • Leakage: Designed so that oxygen is not allowed to leak through any seals or fittings.
  • Gauge: 0 - 100 cm H2O (accuracy +/- 2% of reading).
  • Inspiratory and Expiratory Resistance: 5 cm H2O maximum.
  • Inadvertent PEEP: Less than or equal to 2 cm H2O.
  • Inadvertent Continuing Expiratory Pressure: Less than or equal to 2 cm H2O.
  • Dead Space: Less than or equal to +/- 5.5% of minimum tidal volume.
  • Peak Inspiratory Flow: 100 lpm for 2 seconds.
  • Pressure for Initiation of Breath: -2 cm H2O maximum.
  • Operating Conditions: 0 to 122 °F.
  • Storage/Shipping Conditions: -40 to 140 °F.
  • Oxygen Concentration: 100% or 65% with mixing.
  • Electronic Alarm Battery Life: Greater than 40 hours at room temperature (Low Battery Alarm).
  • Alarm Sound Level: Greater than 60 decibels.
  • CPAP Pressure: Adjustable from 5 - 20 cm H2O.
  • Electronic Alarm Package (optional):
    • High Airway Pressure Alarm:
      • Range: 15 to 80 cm H2O.
      • Accuracy: 5%.
    • Low Airway Pressure Alarm:
      • Range: 0 to 30 cm H2O.
      • Accuracy: 5%.
    • Low Source Gas.
Allied Healthcare AutoVent 4000 Transport Ventilator ConfigurationsMPNConfigurationWeightDimensions#L760Standard3.7 lb2.9" x 9.6" x 6.5"#L760CPAPWith CPAP5.2 lb2.9" x 9.6" x 6.5"#L761With Air Mix Mode4.2 lb2.9" x 9.6" x 6.5"#L761CPAPWith CPAP and Air Mix Mode5.7 lb2.9" x 9.6" x 6.5"#L762With Air Mix Mode and Electronic Alarm Package4.9 lb2.9" x 9.6" x 8"#L762CPAPWith CPAP, Air Mix Mode, and Electronic Alarm Package6.4 lb2.9" x 9.6" x 8"#L763With Electronic Alarm Package4.4 lb2.9" x 9.6" x 8"#L763CPAPWith CPAP and Electronic Alarm Package5.9 lb2.9" x 9.6" x 8"AccessoriesAllied Healthcare AutoVent 4000 Transport Ventilator Accessories

The following accessories are compatible and commonly purchased with the AutoVent 4000 Transport Ventilator:

  • #800149: Internal Air Filter (3 per Package).
  • #800148: CPAP Ventilator Circuit (6 per Package).
  • #L270-220: Oxygen Regulator.
  • #L599-130: Ventilator circuit (10 per Case).
  • #L535026: Oxygen hose, 6' with DISS fittings.

Return Policy

30 Day Return Policy. Free Return. Return Policy: https://help.mfimedical.com/en-US/return-policy-204649