For Sale GE HEALTHCARE B125 Multiparameter Monitor

  • Asking Price :$3,706.25 USD [convert]
  • Condition : Used - Excellent
  • Weight : 25.00 Lbs
  • Qty. Available : 10
  • Date : March 22, 2024
  • Listing # : 2965140
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #2965140

  • Condition: Used - Excellent
  • Brand: GE HEALTHCARE
  • Type: Multiparameter Monitor
  • Model: B125
  • MPN: 2099000-002-564816
  • Depth: 15 inches
  • Height: 15 inches
  • Width: 15 inches
  • Warranty: 90 Days

The GE B125 Patient Monitor (#MFI-GEH-2099000-002-564816) includes NIBP, IBP, Temperature, printer, 3 and 5 lead ECG, extension rack, and battery, as well as Masimo SpO2.

Note: IBP Accessories Sold Separately.

Warranty: 90 Days.

The GE B125 Patient Monitor is a portable multi-parameter unit designed to be used for monitoring, recording, and to generate alarms for multiple physiological parameters of adult, pediatric, and neonatal patients in a hospital environment and during intra-hospital transport.

The B125 Patient Monitor is able to detect and generate alarms for the following ECG arrhythmias: Asystole, Ventricular tachycardia, VT>2, Ventricular Bradycardia, Accelerated Ventricular Rhythm, Ventricular Couplet, Bigeminy, Trigeminy, “R on T”, Tachycardia, Bradycardia, Pause, Atrial Fibrillation, Multifocal PVCs, Missing Beat, Premature Ventricular Contraction (PVC) and Ventricular fibrillation.

GE B125 Patient Monitor Features
  • Seven pre-configured workflow settings for simple set-up.
  • Auto-snapshot of most critical alarms.
  • Alarm reporting options for better alarm management and instant care in cases of arrhythmia, high/low blood pressure, and ECG-lead detachment.
  • Convenient screen lock button for easy cleaning, maintenance, and intra-hospital transport.
  • Capacitive touchscreen for fast response and enhanced user experience.
  • Uninterrupted display of primary ECG-lead waveform and other vital signs across settings.
  • Choice of numerical or continuous waveform monitoring.
  • Large numeric mode that enables critical parameter visibility even up to four meters.
GE B125 Patient Monitor Specifications
  • Weight: 25 lb (11.3 kg).
  • Dimensions: 18" x 18" x 18" (45.7 cm x 45.7 cm x 45.7 cm).
  • Display:
    • Size: 12.1" (diagonal).
    • Resolution: 1280 x 800 pixels (WVGA).
    • Number of Waveforms: Up to 6.
    • Display Layout and Colors: User-configurable.
    • Controls: Capacitive Touch Screen and Trim Knob control and hard keys (standard).
  • ECG:
    • Leads Available:
      • 3-Lead Configuration: I, II, III.
      • 5-Lead Configuration: I, II, III, aVR, aVL, aVF, and V.
    • Sweep Speed: 12.5, 25, or 50 mm/s.
    • Gain Range: 0.5 x , 1 x, 2 x, and 4 x.
    • Heart Rate Accuracy: 30 to 300 bpm, +/- 5% or +/-5 bpm, whichever is greater.
    • 50/60 Hz Power Supply:
      • Monitor: 0.5 to 40 Hz.
      • ST: 0.05 to 40 Hz.
      • Diagnostic: 0.05 to 145 Hz.
    • Pacemaker Detection:
      • Range: 2 to 700 mV.
      • Pulse Width: 0.5 to 2 ms.
    • Arrhythmia Analysis: Asystole, V Fib / V Tach, V Tach, VT>2 R on T, V Brady, Couplet, Bigeminy, Accelerated Ventricular arrhythmia, Multifocal PVCs, A Fib, Missing beat, Pause, Tachy, Brady, Trigeminy.
    • ST Segment Analysis:
      • Numeric Range: -9 to +9 mm (-0.9 to +0.9 mV).
      • Accuracy: +/- 0.2 mm or +/- 10%, whichever is greater, within the measurement range of -8 to 8 mm.
      • Numeric Resolution: 0.1 mm (0.01 mV).
      • ST Trends: Up to 168h.
    • Range:
      • Adult/Pediatric: 4 to 120 resp/min.
      • Neonate: 4 to 180 resp/min.
    • Accuracy: +/- 5% or +/- 5 resp/min, whichever is greater.
    • Gain Range: 0.1 to 5 cm/Ohm.
  • SpO2:
    • GE:
      • Pulse Oximetry Measurement Range: 1 to 100%.
      • Pulse Rate: 30 to 250 bpm.
      • Saturation Measurement Accuracy:
        • Without Motion-Adult/Pediatric Finger Sensor: 70 to 100% +/- 2%
        • Without Motion-Neonate: 70 to 100% +/- 3%.
        • With Motion-Adult/Pediatric/Neonate: 70 to 100% +/- 3%.
        • Low Perfusion-Adult/Pediatric: 70 to 100% +/-3% (1~69% unspecified).
      • Pulse Rate: Without Motion: +/- 2 bpm (adult/pediatric/neonatal).
    • Nellcor:
      • Pulse Oximetry Measurement Range: 1 to 100%.
      • Pulse Rate: 20 to 250 bpm.
      • Saturation Measurement Accuracy:
        • Adult: 70 to 100% +/- 2%.
        • Neo: 70 to 100% +/- 3%.
        • Low Perfusion: 70 to 100% +/- 2%; 0~69% unspecified.
      • Pulse Rate: +/- 3 bpm.
    • Masimo:
      • Pulse Oximetry Measurement Range: 1 to 100%.
      • Pulse Rate: 25 to 240 bpm.
      • Saturation Measurement Accuracy:
        • Without Motion-Adult/Pediatric: 70 to 100% +/- 2%.
        • Without Motion-Neonate: 70 to 100% +/- 3%.
        • With Motion-Adult/Pediatric/Neonate: 70 to 100% +/- 3%.
        • Low Perfusion: 70 to 100% +/-2% (0 to 69% unspecified).
      • Pulse Rate:
        • Without Motion: +/- bpm.
        • With Motion: +/- 5 bpm.
  • NIBP:
    • Measurement Technique: Oscillometric with step deflation.
    • Modes: Manual, Automatic, Stat.
    • Systolic Measurement Range:
      • Adult/Pediatric: 30 to 290 mmHg.
      • Neonate: 30 to 260 mmHg.
    • MAP Measurement Range:
      • Adult/Pediatric: 20 to 260 mmHg.
      • Neonate: 20 to 125 mmHg.
    • Diastolic Measurement Range:
      • Adult/Pediatric: 10 to 220 mmHg.
      • Neonate: 10 to 110 mmHg.
    • Accuracy: Meets AAMI ISO81060-2 and IEC 80601-2-30.
    • Default Initial Inflation Pressure:
      • Adult/Pediatric: 135 +/- 15 mmHg.
      • Neonate: 100 +/- 15 mmHg.
    • Maximum Determination Time:
      • Adult/Pediatric: 2 min.
      • Neonate: 100 +/- 15 mmHg.
    • Over Pressure Monitor:
      • Adult/Pediatric: 294 +/-6 to 330 mmHg.
      • Neonate: 147 +/- 3 to 165 mmHg.
  • Invasive Blood Pressure:
    • Measurement Range: -40 to 320 mmHg (15.3 to 42.7 kPa).
    • Measurement Accuracy; +/- 5% or +/- 2 mmHg, whichever is greater.
    • Frequency Response: 4 to 22 Hz.
    • Transducer Sensitivity: 5 μV/V/mmHg.
  • Temperature:
    • Numerical Display: T1, T2, T2-T1.
    • Measurement Range: 10 to 45 degrees C (50 to 113 degrees F).
    • Measurement Accuracy: +/- 0.1 degrees C without probe.
    • Display Resolution: 0.1 degrees C.
    • Probe: YSI probes recommended by GE Healthcare.
  • Networking:
    • Compatibility: CARESCAPE Network.
    • Wi-Fi Connectivity: IEEE 802.11a/b/g/n.
    • Wi-Fi Security:
      • WPA-Personal.
      • WPA2-Personal.
      • WPA-Enterprise.
      • WPA2-Enterprise.
Item Name: Monitor